Skip to content

Features

What Lynx keeps an eye on for you.

Ten parts, one interface: the agent on your servers, checks from outside, alerts, forecasts, status pages, the weekly report, the AI help, security findings, web traffic analysis and separate areas for your clients.

Every feature in detail

01

Servers from the inside

A small agent measures every minute how your servers are doing — and spots bottlenecks before they turn into outages.

The agent is a single program without dependencies. It runs under its own unprivileged account, opens no port and makes one outgoing connection over HTTPS. If the connection drops, it buffers up to 24 hours of measurements and delivers them later.

Every minute it records CPU per core, load, memory and swap, disk and network throughput, the fill level and inodes of every file system, and the state of MySQL, PHP-FPM and Apache. The ten processes using the most CPU and the ten using the most memory appear by name.

On top of the raw numbers, Lynx runs checks that know what a web server looks like when it is about to struggle: Apache workers running out, a PHP-FPM pool at its limit, MySQL refusing connections, a backup that is older than it should be. The agent currently supports Ubuntu 20.04 to 26.04.

  • Metrics

    CPU, load, memory, disks, network — every minute

  • Services

    MySQL, PHP-FPM and Apache

  • Top processes

    by name only, never with a command line

  • Bottlenecks

    Apache workers, PHP-FPM pools, MySQL connections, backup age

02

Websites from the outside

Four check locations in Nuremberg, Helsinki, Ashburn (USA) and Singapore fetch your pages. An alert is raised only when the locations agree.

A monitor is a question asked from the outside, once a minute by default: does the page answer over HTTPS, with the expected status, and does it contain the text it should? You can send your own headers, log in with basic or bearer authentication and require that a certain text is absent.

Certificates and domains expire quietly. Lynx warns 14 days and again 3 days before a certificate runs out, and 30 and 7 days before a domain does — for every top-level domain whose registry publishes the expiry date. Some registries, the one for .de among them, do not.

Not everything is a website. Ping, TCP and DNS monitors cover mail servers, databases and name resolution. A heartbeat monitor turns the question around: your cron job or backup calls an address when it has finished, and Lynx alerts you when the call does not arrive in time.

  • HTTPS and keyword

    is the right content on the page?

  • Certificate and domain

    a warning well before expiry

  • Ping, TCP, DNS

    for everything that is not a website

  • Heartbeat

    cron jobs and backups report in themselves

03

Alerts

Notifications where your team works — debounced, with quiet hours, escalation and a clear all-clear.

A check has to fail twice in a row before it becomes an incident, and a monitor from the outside only counts as failed when every location that is reporting sees it. A check that flaps — more than three changes within an hour — produces one notification, not a dozen.

You decide who hears about what, and when. Quiet hours follow your time zone and can let serious incidents through. If nobody acknowledges an incident, Lynx notifies the next step after 15 and 30 minutes. A maintenance window holds notifications back for the whole account, one server or one monitor while measuring continues.

When a problem is over, the people who were alerted get the all-clear, with the duration. And Lynx tells you when it can no longer see: a check that cannot measure is reported as blind, and an agent that has been silent for ten minutes becomes an incident of its own.

  • Channels

    email, Telegram, push, Slack, Microsoft Teams, webhook

  • Quiet hours and escalation

    peace at night, and nobody who fails to react is forgotten

  • All-clear

    with the duration, to everyone who was alerted

  • Maintenance windows

    notifications held back, measuring continues

04

Forecasts

“Disk full in ≈ 9 days” — Lynx reads the trend, so you can act during working hours.

Every hour Lynx fits a trend line through the last seven days of each file system: how fast is it filling up, and when will it be full? The same is done for inodes, and optionally for memory. The method is robust against outliers, so a single large upload does not trigger a warning.

A forecast only becomes a warning when the trend is clear and holds for two runs in a row: less than seven days until full is a warning, less than two days is serious. A disk that is merely full of static data stays quiet — there is no trend to report.

  • Disk

    per file system, days until full

  • Inodes

    the limit that many small files hit first

  • Memory

    steady growth, switched on if you want it

  • Two thresholds

    warning under 7 days, serious under 2

05

Status pages

Show your clients openly that everything is running — or that you are already working on it.

A status page shows the monitors you choose, their current state and — if you want — their availability over the last 7, 30 or 90 days. It shows no server details, no software versions, no ports and no causes: your clients see whether it works, not how it is built.

Put the page on your own domain with two DNS records. Lynx checks them, obtains the certificate from Let’s Encrypt and renews it. The page carries noindex, so it is found through your link and not through a search engine.

Announce maintenance in advance and mute the alerts for its duration. Visitors can subscribe by email with a confirmation link and unsubscribe with one click; Lynx stores the address and the time of the confirmation, nothing else.

  • Your own domain

    status.your-company.com with an automatic certificate

  • Announce maintenance

    in advance, with alerts muted meanwhile

  • Email subscription

    visitors hear about incidents automatically

  • History

    availability over the last 90 days

A hand holds a smartphone in the dark; four green status dots glow on its dark screen.

06

Weekly report

Every Monday at 07:00: the past week in one email — short, with numbers.

The report opens with what needs attention right now, then looks back: availability of your monitors, the number and duration of incidents, false alarms, and how each compares with the week before. A number that does not exist is left out rather than shown as zero.

It closes with what is coming up in the next 30 days: disks that are filling, certificates and domains that expire, open security findings. It is switched on for the account owner; anyone else can subscribe, and everyone can unsubscribe with one click.

  • Availability

    of all monitors, compared with the previous week

  • Incidents

    how many, how long, the most serious first

  • Coming up

    disks, certificates and domains within 30 days

  • Unsubscribe

    one click, no login

07

AI help and MCP

With your own Anthropic key, Claude analyses incidents and suggests the first step. Switched off until you agree.

When an incident opens, Claude can read what Lynx measured and write a short assessment: the likely cause and where to start. It never runs anything on your servers. A detailed analysis is available at the push of a button on the incident.

The AI help is switched off until the account owner switches it on and confirms what is sent. It uses your own Anthropic key, within a monthly limit you set. File contents, command lines, user names and credentials are never sent; names and addresses can be replaced before sending.

Through MCP you can ask Lynx from claude.ai, Claude Desktop or Claude Code: which servers have a problem, what happened last night? The access is read-only, has to be enabled by the owner and is authorised per user.

  • Summary in the alert

    likely cause and first step in a few sentences

  • Detailed analysis

    at the push of a button on the incident

  • Cost limit

    you decide how much it may cost per month

  • MCP access

    ask Lynx directly from claude.ai, Claude Desktop or Claude Code

08

Security findings

Once a night Lynx compares what is installed on your servers with what is known to be vulnerable.

The agent reports the installed packages; the central matches them against public vulnerability databases and the security notices of the distribution. A finding is rated critical only when the affected service is measurably reachable from the outside — so the list starts with what matters.

Software that has reached its end of life is listed too, and a daily check looks for files and folders in the web root that anyone can write. Pending updates, pending security updates and a required restart appear in the facts of each server. Findings never appear on a public status page.

  • Known vulnerabilities

    in installed packages, checked every night

  • End of life

    software that no longer receives fixes

  • Web root permissions

    files and folders that anyone can write

  • Pending updates

    security updates and required restarts per server

09

Web traffic

Who visits your pages – people, search engines, AI crawlers or attackers – counted on your own server and switched on per server, by you.

The agent reads the access log of Apache or nginx and counts per minute and page: requests, visits, bytes sent and status codes. Only these totals go to Lynx – no IP addresses, no user agents, no single requests.

It is off until the account owner switches it on for a server and confirms that their privacy policy covers it. You can switch it off at any time, and delete the counted data straight away if you wish.

  • People and bots

    five classes, by name and behaviour

  • Pages and errors

    top pages, error pages with referrer, downloads

  • Totals only

    no IP address leaves the server, not even as a hash

  • Switched on by you

    per server, by the owner, with a clear explanation

010

Agencies and sub-tenants

One account for all your clients — each in a separate area, with their own access.

A sub-tenant is a closed area for one client: their servers, monitors, alert channels and status page. You see all of your clients; a client sees only their own area. The separation is enforced in the database, not only in the interface.

Four roles decide who may do what: the owner manages users and installs agents, technicians acknowledge incidents and change alert rules, readers see everything and change nothing, and end customers see their own servers and incidents.

  • Sub-tenants

    one closed area per client

  • Roles

    owner, technician, reader, end customer

  • Status page per client

    on the client’s own domain

  • One invoice

    everything counts towards the agency’s plan

Ready for the first heartbeat?